Arthrex - Patella Fracture PEEKPower Tibial Head Fracture Plates Lateral and Posteromedial A combination of titanium locking screws and a radiolucent carbon reinforced PEEK plate. PEEKPower Humeral Fracture Plate Anatomically designed radiolucent multidirectional locking plate made of carbon fiber reinforced PEEK in combination with titanium screws. Ankle Fracture Plating System, CHARLOTTE Dr. Adam Schiff demonstrates a Fifth Metatarsal procedure using VariAx fracture plates. Suture holes in the plate can be optionally used for soft-tissue reattachment or ligament bracing.
Scapula Plating System | Acumed It includes 4.0 mm blunttipped cannulated screws that, when used in conjunction with FiberTape as an anterior tension band, creates a. Stainless Steel, Type I Anodized titanium, and machined . Pain is usually moderate and manageable with over-the-counter medications. 2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. The purpose of this study was to determine if a tension band constructed of FiberWire (Arthrex, Naples, FL), a high-strength polyester and polyethylene suture, will provide fixation that is equivalent to an 18-gauge metal wire tension band. Any compromise of the joint surface is likely to lead to degenerative joint disease. Last reviewed by a Cleveland Clinic medical professional on 11/12/2021. simple fall onto the knee or motor vehicle injuries) or indirectly following a forceful contraction of the quadriceps with the knee in a flexed position [ 2 ]. Surgical Technique Videos | 07:26 | English | 07/05/2016 | VID1-00635-EN B, Surgical Technique Videos | 09:57 | English | 04/04/2022 | VID1-002599-en-US A, Surgical Technique Animations | 01:54 | English | 03/19/2020 | AN1-00144-EN D, 09:57 | English | 04/04/2022 | VID1-002599-en-US A, 06:28 | English | 01/06/2020 | VID1-000674-en-US A, 07:26 | English | 07/05/2016 | VID1-00635-EN B, 01:54 | English | 03/19/2020 | AN1-00144-EN D, 01:08 | English | 09/20/2018 | PAN1-00144-EN D, 09:28 | English | 05/19/2020 | VID1-000948-en-US A, 01:20 | English | 11/10/2017 | VID1-00639-EN C, 08:25 | English | 10/23/2017 | VPT1-00849-EN A. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. 3.5 mm Multi-Directional Locking Screws or 3.5 mm Low Profile
Linda Bingel - Senior Partnerships Manager - Oviva | LinkedIn Outcomes after locked plating of displaced patella fractures: a Secure and stabilize ankle fractures with Arthrex's ankle fracture and distal tibia plating system. 2.7 mm, 3.5 mm and4.0 mm locking screws that can be inserted into hole as shown in the illustration below. This video depicts a correction of a hallux valgus deformity using a lapidus procedure, a fusion of the first metatarsal with the medial cuneiform. If you think you can, but it is still painful, its probably best not to try until you have been diagnosed.
Removal of the syndesmotic screw after the surgical treatment of a Low Profile VA Locking Screw, 3.0 x 10 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 12 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 14 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 16 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 18 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 20 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 22 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 24 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 26 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 28 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 30 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 32 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 34 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 36 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 38 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 40 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 40 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 42 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 44 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 46 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 48 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 50 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 52 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 54 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 56 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 58 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 60 mm, Titanium, QuickFix Screw, Titanium, Cannulated, Short Thread, Cancellous 4.0 x 28 mm, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 30 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 32 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 34 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 36 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 38 mm, Titanium, Handle, Quick Coupling Ratcheting, Cannulated, Bone Reduction Forceps, Curved, Pointed, qty 2, Drive Shaft, Cannulated, QC, T15 Hexalobe, Screw Holding Sleeve for 2.7, 3.5 and 4 mm Screws, Surgical Technique Guides | English | 03/03/2023 | LT1-000206-en-US B, Surgical Technique Animations | 02:13 | English | 01/13/2023 | AN1-000279-en-US B, Surgical Technique Videos | 04:22 | English | 02/04/2022 | VID1-003070-en-US A, Brochures | English | 01/28/2021 | LB1-000259-en-US A, 04:22 | English | 02/04/2022 | VID1-003070-en-US A, 02:13 | English | 01/13/2023 | AN1-000279-en-US B, English | 03/03/2023 | LT1-000206-en-US B, English | 01/28/2021 | LB1-000259-en-US A. Our plating portfolio ranges from indication specific plates and patented Smartlock technology to streamlined instrumentation for ease-of-use in the OR. The anterior component is the optimal plate position after OW-HTO correction positioned below the patellar tendon and the 2 poste- and to feedback this anatomical position to the pre- rior legs are placed between the posterior surface of the osteotomy guide position. the substantial bone of the sustentaculumtali. representative; search this website for additional product It is a serious type of knee injury that can affect all types of men and women athletes. Innovative instruments are included along with sternal wire drivers, Weber clamps, drill guides, and Stout wire cutters, giving surgeons all necessary instruments needed in one convenient set. These cookies will be stored in your browser only with your consent. Watch to help you deliver support and guidance to your Utilizes multiple A.L.P.S. cpt code for lateral column lengthening. options for calcaneus fracture management.. This website uses cookies to improve your experience while you navigate through the website. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. Naples, FL; 2013. Arthrex, Inc. products are designed without any latex components or packaging. 3-Hole Extended, These two new plate designs expand upon Zimmer Biomets The A.L.P.S. surgeon to direct the screw up to 15 degrees (30 degreecone of OrthoLine plates can be contoured using size-specific bending irons and cannulated bending plugs, which can also function as K-wire holes in any locking screw hole. The set is designed to fix transverse patella fractures. 1. Tabs allow the surgeonto place screws into the cuboid, thus Suture holes can be used for soft-tissue attachment or ligament bracing. Non-Locking Screws. a locking calcaneus plate design that address comminuted fractures The Right Material For Each Indication Properties of Titanium Alloy Implants Corrosion resistant Low modulus of elasticity (prevents stress shielding) Enhanced MRI & CT resolution (fewer artefacts) Non-allergenic Permanent implantation option Properties of Stainless Steel Implants Ductility (bendable) High strength (significantly stiffer than titanium alloy) Reduced oss. The Patella Fracture System includes everything needed to repair transverse patella fractures. 1 Tension-band wiring and cannulated screws have been the most commonly used techniques for the management of . options for calcaneus fracture management.. plates are designed for more comminuted fractures that require Tight screw density on the distal and proximal ends with larger bridges near the center of the plate allows surgeons to fit more screws in the same footprint than competitive plates. Compared to traditional K-wires, this construct has been shown to be stronger.1. Apple Watch and iPhone are trademarks of Apple, Inc., registered in Solving complicated fractures with simple innovative solutions - Plating that fits. Small and large standard plates are designed posterior fixation. All fibula plates are engineered to work seamlessly with our proven Syndesmosis TightRope implants. Keywords: Patella fracture, Knee, Trauma, Review, Tension band, Plate fixation, Patellectomy Introduction Patella fractures account for 1% of fractures in adults and are seen in all age groups. A 3.5 mm Low Profile Non-Locking Cortical An interactive learning environment for enhancing education and training. Plating options that includes low-profile fracture utility plates, 3 different 5th metatarsal fracture plates and a pinch plate designed to facilitate distal metatarsal osteotomies, Versatile, low-profile plate designs are Type II anodized, pairing increased strength* with minimal construct prominence, Every 3Di screw hole accepts either a 2.0mm or 2.4mm non-locking or polyaxial locking screw, addressing variations in fracture patterns and patient anatomies. requirements present in the trabecular anatomy of the calcaneus. A recent study evaluated construct failure after an open reduction and plate fixation and reported a construct failure rate of 6.9% of which 1.9% were related to broken plates. titanium plates offerTiMAXsurface treatmentfor the It covers the incision, the desired outcome, the osteotomy and then two different methods of fixation. K-wire fixation with metal tension band were used for fixation in 315 (70%) patients and cannulated screws were used with tension band for fixation in 133 (30%). Your healthcare provider may recommend trying to avoid stairs, squatting and bending, when possible, to limit stress on your knee and prevent future complications. All plates have a low-profile thickness of 1.6 mm with screws sitting flush. Some people report long-term symptoms of pain or stiffness, and some choose to continue wearing a knee brace for support. [13] showed that surgical experience may improve the surgeon's competency in prevention of lateral hinge fractures, highlighting the need to be . The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. Foot & Ankle Ankle Fracture Management System A comprehensive set for the treatment of common ankle fracture injuries. 1 ). Calcaneal Fracture System Designed to be the most comprehensive solution for calcaneal fracture fixation perimeter and percutaneous plates. The system is made of titanium and offers three plating options, each in various sizes. ecosystems across the episode of care. A patella fracture is a break in your kneecap the small, flat bone that covers and protects your knee joint like a shield. Plating options that includes low-profile fracture utility plates, 3 different 5th metatarsal fracture plates and a pinch plate designed to facilitate distal metatarsal osteotomies Versatile, low-profile plate designs are Type II anodized, pairing increased strength* with minimal construct prominence Patellar plating. provide both strength to the inner area of the plate, and